Delay On Operate 8-Pin Type: Output relay is energized at the completion of the time interval which is initiated by the application of input voltage. 11-Pin Type: Same as above except, closing the control switch after time out will de-energize the relay and reset the timer. Opening the switch will initiate another time interval. Closing the control switch during timing will reset the time to zero and inhibit timing until opened again.Interval On (Input Controlled) 8-Pin Type: Output relay is energized by the application of input voltage. The time interval is initiated at the same time with the relay de-energized at the completion of the time interval. 11-Pin Type: Same as above. Closing the control switch will have no effect on timing or the state of the relay. Recycler (Initially Off) 8-Pin Type: Output relay will begin cycling at a 50% duty cycle with the application of input power. The initial state of the relay will be de-energized. 11-Pin Type: Same as above except, closing the control switch will de-energize the relay and inhibit timing until it is once again opened, at which time it will start from zero time. Recycler (Initially On) 8-Pin Type: Output relay will begin cycling at a 50% duty cycle with the application of input power. The initial state of the relay will be energized. 11-Pin Type: Same as above except, closing the control switch will energize the relay and inhibit timing until it is once again opened, at which time it will start from zero time. Delay On Release 11-Pin Only: Output relay is energized by the closing of the control switch with the input applied of the application of input voltage with the control switch already closed. | The time interval will be initiated by the opening of the control switch with the relay de-energized at the completion of the time interval. Closing the control switch after time out will energize the relay in preparation for another time interval. Closing the switch during timing will reset the time to zero and inhibit timing until opened again. Inverted Delay On Release 8-Pin Type: No Time Delay - Instantly ON 11-Pin Type: Output relay will energize with the application of the input voltage when the control switch is open. Control switch closing will de-energize the relay. A timing interval will be initiated with the opening of the control switch, at the completion of which the relay will energize. With the control switch closed upon application of input voltage, the relay will wait until the control switch is opened to initiate a time interval after which the relay will energize. Closing the control switch during timing will reset the time to zero and inhibit timing until opened again. Interval On (Switch Controlled) 11-Pin Only: Output relay is energized by the application of input voltage with the control switch closed or the closing of the control switch with the input applied. Immediately upon either, timing is initiated with the relay de-energized at the completion of the time interval. Closing the control switch after time out will reset the timer, energize the relay, and initiate another time interval. Closing the control switch during timing will have no effect on timing or the state of the relay. Interval Off 11-Pin Only:Output relay will initially be energized with the application of the input voltage when the control switch is open. Control switch closing will de-energize the relay and start a time interval. At the completion of the time interval, the relay will energize. With the control switch closed upon application of input voltage, a time interval will be initiated after which the relay will energize. Closing of the control switch during timing will have no effect on timing or the state of the relay. |