| RECYCLE TIMING - The first delay period begins when the input voltage is applied. At the end of the first delay, or "OFF" period, the internal relay pulls in, and the second delay, or "ON" period begins. When the second delay period ends, the relay drops out. This recycling sequence will continue until the removal of input voltage. When input voltage is removed, the relay drops out. |  |
| DPDT, 2 Form "C" |  |
| AC or DC OPERATED | | NTE Type No. | Nom. Volt. | Contact Arr. | Input Cur. Nom. | Max. Contact Cur, @ 28VDC or 120VAC | Diag. No. | | R26-11AD10-12 | 12VAC/DC | DPDT | 167mA | 10A | D54 | | R26-11AD10-24 | 24VAC/DC | DPDT | 83mA | 10A | D54 | | R26-11AD10-120 | 120VAC/DC | DPDT | 17mA | 10A | D54 |
| ACCESSORIES | | Mounting Styles | Description | NTE Type No. | | Surface Mount | 8-Pin Octal | R95-101 | | Panel Mount | 8-Pin Octal | R95-118 | | DIN Rail Mount | 8-Pin Octal | R95-113 | | 8-Pin Octal | R95-181 |
| | | Dimensional Drawing | Timing Range Chart | | D54 | |  |  |
Electrical Specifications
Contact Rating: 10 Amps 240VAC or less, 1/3 HP, 240VAC or 120VAC, Pilot Duty 345VA, 120VAC or 240VAC, 50/60Hz Life: 500,000 operations at full load Mechanical Life: 7,000,000 operations at no load Input Nominal Input Voltages: See Chart Steady State Input Current: See Chart Timing Timing Adjustment Modes Available: See Timing Range Chart Repeat Accuracy ±0.5% - after established at steady temperature (4 hours) Timing Tolerance at High End of Range: -0, +10% Timing Tolerance at Low End of Range: +0, -50% Reset Time: 60mS Typ Protection Transient: Surge Test 10,000V for 20mS Dielectric Breakdown: Coil To Contact: 1850 VAC Across Open Contact: 1850 VAC Environmental Characteristics Operating: -20°C to +55°C Weight Std: 4.5 ozs. (130 grams) - approx |